Home FQ Manufacturers - Fastening Systems and Solutions
  Tapes, Cords and FabricsAccessories and TrimmingsZips, Sliders and Chains

 
Cut Zips
 
SAMPLE 1 No.3 Closed End with N31A Slider

ATTRIBUTE
TEST RESULTS
REQUIREMENT
Lateral Strength Chain 922.49 N Pass 600N MIN
Loads To Open 100G Pass 350G MAX
Loads To Close 110G Pass 350G MAX
Reciprocation > 500 Pass 500 MIN
Strength To Bottom Stop 115.8N Pass 60N MIN
Slider Lock Holding 42.73N Pass 40N MIN
Strength Top Stop 106.98N Pass 80N MIN
 
SAMPLE 3 No.5 Closed End with N51A Slider

ATTRIBUTE
TEST RESULTS
REQUIREMENT
Lateral Strength Chain 990.8 N Pass 700N MIN
Loads To Open 110G Pass 500G MAX
Loads To Close 120G Pass 500G MAX
Reciprocation > 500 Pass 500 MIN
Slider Lock Holding 88.9N Pass 60N MIN
Strength To Bottom Stop 116.6N Pass 80N MIN
Strength Top Stop 198.22N Pass 120N MIN
 
SAMPLE 3 No.5 Open End with N51A Slider

ATTRIBUTE
TEST RESULTS
REQUIREMENT
Lateral Strength Chain 990.8 N Pass 700N MIN
Loads To Open 110G Pass 500G MAX
Loads To Close 120G Pass 500G MAX
Reciprocation > 500 Pass 500 MIN
Slider Lock Holding 88.9N Pass 60N MIN
Open End Box Pull Off 123.1N Pass 120N MIN
Lateral Strength Open End 180.8N Pass 120N MIN
Strength Top Stop 198.22N Pass 120N MIN
 
SAMPLE 4 No.5 Plastic Closed End with D51A Slider

ATTRIBUTE
TEST RESULTS
REQUIREMENT
Lateral Strength Chain 61.4 N Pass 60N MIN
Loads To Open 2.07N Pass 500G MAX
Loads To Close 2.17N Pass 500G MAX
Reciprocation > 500 Pass 500 MIN
Strength To Bottom Stop 124.7N Pass 70N MIN
Slider Lock Holding 123.07N Pass 50N MIN
Strength Top Stop 195.73N Pass 100N MIN
 
SAMPLE 5 No.5 Plastic Open End with D51A Slider

ATTRIBUTE
TEST RESULTS
REQUIREMENT
Lateral Strength Chain 61.4 N Pass 60N MIN
Loads To Open 110G Pass 500G MAX
Loads To Close 120G Pass 500G MAX
Reciprocation > 500 Pass 500 MIN
Slider Lock Holding 88.9N Pass 60N MIN
Open End Box Pull Off 208.1N Pass 80N MIN
Lateral Strength Open End 165.5N Pass 70N MIN
Strength Top Stop 195.73N Pass 100N MIN
 
 
#top